dc.description.abstractRESUMO: O processo de soldagem é amplamente difundido na indústria nas mais diferentes atividades, sendo considerado o mais importante método de união de metais. No entanto, durante a execução de tal processo são gerados poluentes nocivos à saúde humana, conhecidos como fumos metálicos e gases tóxicos. Sendo assim, a aplicação de uma ventilação forçada se torna uma alternativa para reduzir este problema, de modo que esta evita a dispersão dos contaminantes, minimizando os riscos e garantindo melhores condições de trabalho. Visando propiciar um ambiente de trabalho salubre e evitar que a saúde dos colaboradores seja prejudicada pela inalação dos gases e fumos resultantes do processo de soldagem, no presente trabalho foi realizado o dimensionamento de um sistema de ventilação local exaustora para a estação de soldagem de uma empresa da região. O projeto foi desenvolvido para atender as 10 bancadas de solda presentes na célula, tendo captação em cada um dos pontos com braços extratores que se adequam a diferentes situações de operação. Estes, são conectados a uma tubulação que direciona o ar exaurido para um filtro responsável por coletar o particulado, e por fim, foi determinado um ventilador que atendesse a vazão e pressão do sistema.pt_BR
dc.description.abstractABSTRACT: The welding process is widely used in the industry in the most different activities, being considered the most important method of joining metals. However, during the execution of this process, pollutants that are harmful to human health, known as metallic fumes and toxic gases, are generated. Thus, the application of forced ventilation becomes an alternative to reduce this problem, in order to prevent the spread of contaminants, minimizing risks and ensuring better working conditions. Aiming to provide a healthy working environment and prevent the health of employees from being harmed by the inhalation of gases and fumes resulting from the welding process, in this work, a local exhaust ventilation system for a company's welding station was carried out. The project was developed to meet the 10 solder benches present in the cell, with extraction at each point with extracting arms that suit different operating situations, these are connected to a pipe that directs the exhausted air to a filter responsible for collecting the particulates, and finally, a fan was determined to meet the system's flow and pressure.pt_BR
dc.format.extent55 f.pt_BR
dc.languagept_BRpt_BR
dc.rightsacesso_abertopt_BR
dc.subjectSoldagempt_BR
dc.subjectExaustãopt_BR
dc.subjectVentilação local exaustorapt_BR
dc.titleDimensionamento de um sistema de ventilação local exaustora para estação de soldagempt_BR
dc.typetccpt_BR
dc.publisher.localSão Mateuspt_BR
ifes.campusCampus_Sao_Mateuspt_BR
ifes.advisor.latteshttp://lattes.cnpq.br/0745670592897942pt_BR
ifes.course.undergraduateEngenharia Mecânica
dc.contributor.memberSiqueira, Alan Patrick da Silva
dc.contributor.memberSantos, Walber Ronconi dos
ifes.member.latteshttp://lattes.cnpq.br/5038330645330902pt_BR
ifes.member.latteshttp://lattes.cnpq.br/5116556512998410pt_BR


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record